Summary for Test 2018-08-21-1-2
Test performed: ASTM A775-07b-re14Project Information
Project Identifiers | Project ID: 211669 DEA: 022C0904 EFIS: 0200000161 |
---|---|
DIST-CO-RTE-PM | 02-PLU-70-50.6/51.7 |
Award Date | 11/16/2016 |
Closeout Date | 11/12/2020 |
Work Description | BRIDGE WIDENING AND DECK REPLACEMENT, HMA, MGS AND CULVERT REPLACEMENT |
Location Description | PLUMAS COUNTY NEAR QUINCY FROM 0.6 MILE WEST TO 0.5 MILE EAST OF SPRING GARDEN BRIDGE OVERHEAD |
QA Service Level | 1 (Verified on 10/25/2016) |
Sample Information
Sample Taken Date | 08/21/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/24/2018 |
Sample type | Quality Assurance | A brief description of the sample | Green Epoxy Coated Rebar |
The quantity of what the sample constitutes | 21959 lbs total | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Thompson |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 510-376-7155 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rebar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B9-071-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4078485 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | Rebar Coating Specification | ASTM A775 | |
Rebar Size (#) | 5 | Rebar Coating Color | Green |
Rebar Manufacturer | Cascade Steel CMC Steel AZ | Rebar Coater | CMC Brighton CO |
Rebar Powder Manufacturer | Unknown | Release Number | Unknown |
Quality Assurance Code | Unknown |
Test Details
DIME Sample ID: 2018-08-21-1
DIME Test ID: 2018-08-21-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)
Test Release Date: 2018-09-05
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/29/2018
Total Number of Holiday: 0
Total Length: 2.6
Holidays Per Linear Foot of Bar: 0
Holiday Test Pass/Fail: Pass
Bend Test Pass/Fail: Pass
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/29/2018 ✔