Summary for Test 2018-04-12-13-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 212497 DEA: 024E0204 EFIS: 0200020196 |
---|---|
DIST-CO-RTE-PM | 02-SHA-299-77.8/79.7 |
Award Date | 02/01/2018 |
Closeout Date | 08/14/2019 |
Work Description | PULVERIZE AND RECONSTRUCT PAVEMENT, AND WIDEN WITH AB, HMA, & RHMA |
Location Description | SHASTA COUNTY NEAR BURNEY FROM 0.2 MILE WEST OF SONOMA STREET TO 0.3 MILE WEST OF ROUTE 89 |
QA Service Level | 1 (Verified on 06/06/2017) |
Sample Information
Sample Taken Date | 04/12/2018 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/13/2018 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA, PG 64-28 M |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Cindy | Last name of sampler or witnessed by | Bryant |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | D77323 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Hat Creek - Shaw Pit Facility | Transportation Laboratory (TL) Number | 853526 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | JMF 18-02-S1a | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | Not set |
Sublot number | Not set | HMA Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-04-12-13
DIME Test ID: 2018-04-12-13-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2018-08-20
Test Results
Number of tests: 3
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 05/03/2018
Percent Air Voids: 4.0 %
Percent Air Voids 2: 4.3 %
Percent Air Voids 3: 3.9 %
Percent Air Voids Average: 4.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/20/2018 ✔