Summary for Test 2018-07-14-7-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212731
DEA: 07318004
EFIS: 0715000280
DIST-CO-RTE-PM07-LA-10-22.3/28.2
Award Date11/16/2017
Closeout Date06/16/2021
Work DescriptionTREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62
QA Service Level1 (Verified on 03/21/2018)

Sample Information

Sample Taken Date07/14/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/06/2018
Sample typeQuality Assurance A brief description of the sampleCouplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byRuben Last name of sampler or witnessed bySanduval
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau BarSplice Transportation Laboratory (TL) NumberC672056
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar Manufacturer Gerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size5 Coupler ModelDBL BRL Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)80172 Rebar Heat Number(s) 65031313
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-07-14-7
DIME Test ID: 2018-07-14-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-16

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/09/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#5/16mm0.312826091160Service SpliceBrian

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/9/2018