Summary for Test 2018-07-28-1-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212731 DEA: 07318004 EFIS: 0715000280 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-22.3/28.2 |
Award Date | 11/16/2017 |
Closeout Date | 06/16/2021 |
Work Description | TREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62 |
QA Service Level | 1 (Verified on 03/21/2018) |
Sample Information
Sample Taken Date | 07/28/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/06/2018 |
Sample type | Quality Assurance | A brief description of the sample | Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Ruben | Last name of sampler or witnessed by | Sanduval |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Nucor BarSplice | Transportation Laboratory (TL) Number | C672059 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | NA | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 5 | Coupler Model | DBL BRL Zap Screwlok |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | 7048 | Rebar Heat Number(s) | 350000544 |
Rebar Size 2 | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-07-28-1
DIME Test ID: 2018-07-28-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-08-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/09/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | 1 | #5/16mm | 0.31 | 30250 | 97580 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 8/9/2018 ✔