Summary for Test 2018-07-19-26-4

Test performed: ASTM A416-15

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date07/19/2018 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/18/2018
Sample typeQuality Assurance A brief description of the sample.5 in Prestressing Strand
The quantity of what the sample constitutes23 From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byHiranaga
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameSumiden Wire Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand CommentsUnknown
Reel/Coil/Pack Number(s) Number of CoilsUnknown
Group Number10888 Strand Diameter.5 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0587818, S0587518, S0587718 Mfg. Lot Number(s)NA
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2018-07-19-26
DIME Test ID: 2018-07-19-26-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2018-08-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/30/2018
UTM: 120KIP
Temperature: 72 F
Extensometers: E88768
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0587518S531259-70.151426763846328.51.83Brian

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 7/31/2018