Summary for Test 2018-05-27-3-2

Test performed: AASHTO T329-13

Project Information

Project IdentifiersProject ID: 213058
DEA: 010G6804
EFIS: 0117000045
DIST-CO-RTE-PM01-MEN-253-0.0-17.6 / 30-28.4 / 23.3-19.8
Award Date03/22/2018
Closeout Date08/07/2019
Work DescriptionCOLD PLANE, PLACE HMA AND MICROSURFACING
Location DescriptionMENDOCINO COUNTY NEAR BOONVILLE FROM 0.5 MILE WEST OF ANDERSON CREEK BRIDGE TO ROUTE 253/101 SEPARATION
QA Service Level1 (Verified on 04/27/2018)

Sample Information

Sample Taken Date05/27/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/30/2018
Sample typeVerification A brief description of the sample3/4 Cold feed
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJack Last name of sampler or witnessed byMartin
Title of samplerTET Telephone number of samplerUnknown
Laboratory sample identification61953 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGranite Ukiah Transportation Laboratory (TL) Number978561
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot numberNot set
Sublot numberNot set HMA Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-05-27-3
DIME Test ID: 2018-05-27-3-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: AASHTO T329-13: Standard Method of Test for Moisture Content of Asphalt Mixtures by Oven Method (Moisture Content)
Test Release Date: 2018-07-24

Test Results


Input Type: Calculated
Tester's full name: Leif Ayres
Date of test: 07/24/2018
Moisture Content: 0.00 %
Percent Change: 0 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/24/2018