Summary for Test 2018-07-06-6-2
Test performed: ASTM C127-12Project Information
Project Identifiers | Project ID: 210808 DEA: 020E0904 EFIS: 0200000016 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R29.3/R31.1,R45.0/R45.8 |
Award Date | 02/03/2016 |
Closeout Date | 10/21/2020 |
Work Description | REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT |
Location Description | IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE. |
QA Service Level | 1 (Verified on 09/23/2015) |
Sample Information
Sample Taken Date | 07/06/2018 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/13/2018 |
Sample type | Per Request | A brief description of the sample | RC Lightweight coarse aggregate |
The quantity of what the sample constitutes | 1 5gal bucket | From where was the sample collected | Source |
First name of sampler or witnessed by | Redding Concrete | Last name of sampler or witnessed by | not provided |
Title of sampler | not provided | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | redding concrete | Transportation Laboratory (TL) Number | c340593 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | not provided |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | redding concrete |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Unknown | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
HMA Pay | No |
Test Details
DIME Sample ID: 2018-07-06-6
DIME Test ID: 2018-07-06-6-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: ASTM C127-12: Standard Test Method for Relative Density (Specific Gravity) and Absorption of Coarse Aggregate
Test Release Date: 2018-07-23
Test Results
Basis for relative density testing: Saturated Surface Dry
Input Type: Measured
Tester's full name: Bang Nguyen
Date of test: 07/23/2018
Mass of sample saturated surface dry aggregate: 2602.2 grams
Mass of sample in water: 1118.3 grams
Mass of sample after oven drying: 2206.8 grams
Specific Gravity: 1.75
Density: 1750 kg/m^3
Absorption: 17.9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/23/2018 ✔