Summary for Test 2018-06-20-19-1
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 208945 DEA: 07288604 EFIS: 0700021080 COOP: 074663 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-6.0-9.4 |
Award Date | 09/02/2011 |
Closeout Date | Not set |
Work Description | Gerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing. |
Location Description | Port of Long Beach (District 7) |
QA Service Level | 1 (Verified on 06/03/2013) |
Sample Information
Sample Taken Date | 06/20/2018 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/03/2018 |
Sample type | Independent Assurance | A brief description of the sample | A490 Bolt assy |
The quantity of what the sample constitutes | 1 lot | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | IQA Inspector | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | LeJeune Bolt Company | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-077-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412647 |
---|---|---|---|
Heat Number(s) | 10531190, 62143479, 262342 | Nut Mfg. Lot Number(s) | 27106-6214347903Z |
Washer Mfg. Lot Number(s) | D3644-114Z | Bolt Specification | A490 |
Bolt Length(s) | Nut Specification | A563 DH | |
Washer Specification | F436 | Finish | Geomet |
Diameter/Size | 1-1/4" x 4-1/4" | Bolt Mfg. Lot Number | 28201-10531190Z |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2018-06-20-19
DIME Test ID: 2018-06-20-19-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2018-08-09
Test Results
Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/20/2018
UTM: 400KIP
Temperature: no data
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Wedge Angle (deg) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 19A | 28201-10531190Z | 1-1/4\" | 158001 | 702.8 | 6 | A490 Bolt | Brian |
General comments (publicly viewable) (Max 1000 characters): A490 Bolt
Test Graph
Source: Partner Data Point FileTest was verified on 8/2/2018 ✔