Summary for Test 2018-06-28-1-3
Test performed: ASTM A970-15e1Project Information
Project Identifiers | Project ID: 212741 DEA: 020E1804 EFIS: 0200000022 |
---|---|
DIST-CO-RTE-PM | 02-PLU-89-29.8/30.2 |
Award Date | 12/13/2017 |
Closeout Date | 12/17/2021 |
Work Description | BRIDGE REPLACEMENT |
Location Description | PLUMAS COUNTY NEAR CANYON DAM FROM 0.2 MILE SOUTH TO 0.3 MILE NORTH OF LAKE ALMANOR SPILLWAY |
QA Service Level | 1 (Verified on 12/06/2017) |
Sample Information
Sample Taken Date | 06/28/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/05/2018 |
Sample type | Quality Assurance | A brief description of the sample | HRC 120 T-Heads |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | QA | Telephone number of sampler | 323 229-8771 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rebar Tracy, HRC | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-098-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Production Testing |
---|---|---|---|
Rebar Heat Number(s) | 4075194 | Head Manufacturer Lot Number(s) | JA33077 |
Rebar Size | 9 | Headed Bar Model Name | HRC 120 |
Size of Head | Reduced Size - 4x | Head Connection Type | Friction Weld |
Head Shape | Square | Rebar Manufacturer | Gerdau |
Head Manufacturer | Gerdau HRC | Head Fabricator | HRC |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2018-06-28-1
DIME Test ID: 2018-06-28-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2018-07-17
Test Results
Number of Headed Bar Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/10/2018
UTM: 400KIP
Temperature: 72 F
Num | Lot # | Area (sqin) | Peak Load (lbf) | Tensile Strength (psi) | Comments | Tested By |
---|---|---|---|---|---|---|
1 | 1 | 1 | 97450 | 97450 | Bar Broke | Brian |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/10/2018 ✔