Summary for Test 2018-06-15-17-2
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 210569 DEA: 083555V4 EFIS: 0814000086 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-42.5/46.0 |
Award Date | 11/05/2015 |
Closeout Date | 01/18/2022 |
Work Description | WIDEN I-15, RECONSTRUCT 3 IC'S, CONSTRUCT 2 NEW BR AND WIDEN 3 BR. |
Location Description | SAN BERNARDINO COUNTY IN VICTORVILLE FROM 0.5 MILE NORTH OF MOJAVE DRIVE TO 1.5 MILE NORTH OF STODDARD WELLS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 06/15/2018 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/21/2018 |
Sample type | Quality Assurance | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | ravinder | Last name of sampler or witnessed by | singh |
Title of sampler | TE | Telephone number of sampler | Unknown |
Laboratory sample identification | 934-0615 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | 20180615 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | 54 0483 |
Material Information
Material Type | Concrete | The concrete mix design number | S1T172A |
---|---|---|---|
The truck number from where the sample was collected | NA | The batch plant ticket number from where the sample was collected | 840912 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | site | Where the material sample would have been placed if not sampled | Mojave River Bridge Widenings 54 0483 starter wall at 6l and7l |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-06-15-17
DIME Test ID: 2018-06-15-17-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-07-06
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 06/29/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 126560 lb
Maximum load on cylinder 2: 112520 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 4446.9 psi
Compressive strength of cylinder 2: 3966.2 psi
Compressive strength (to nearest 10 psi): 4210 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/29/2018 ✔