Summary for Test 2014-04-17-10484428-1
Test performed: CTM 214-August 2010Project Information
Project Identifiers | Project ID: 10016 DEA: 06342524 EFIS: 0600000381 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R71.8/74.5 |
Award Date | 04/23/2013 |
Closeout Date | 10/19/2020 |
Work Description | NEW EXPRESS HIGHWAY |
Location Description | FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE |
QA Service Level | 1 (Verified on 07/23/2013) |
Sample Information
Sample Taken Date | 04/17/2014 | Sample Unique Key | 10484428 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/25/2014 |
Sample type | Annual Source Testing | A brief description of the sample | 1x4 |
The quantity of what the sample constitutes | 1 Bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Mark | Last name of sampler or witnessed by | Mengoni |
Title of sampler | Not set | Telephone number of sampler | Not set |
Laboratory sample identification | 14CPCC-0131 C812735A | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Vulcan Sanger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | NA |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
The plant number | Not set | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2014-04-17-10484428
DIME Test ID: 2014-04-17-10484428-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 214-August 2010: Method of Test for Soundness of Aggregates by Use of Sodium Sulfate
Test Release Date: 2014-04-18
Test Results
What size aggregate is being tested?: Coarse Aggregate
Input Type: Calculated
Tester's full name: Thomas Stinnett
Date of test: 04/17/2014
Percentage Loss of material retained on 2 x 1 ½ in. sieve: no data
Percentage Loss of material retained on 1 ½ x 1 in. sieve: no data
Percentage Loss of material retained on 1 x ¾ in. sieve: no data
Percentage Loss of material retained on ¾ x ½ in. sieve: no data
Percentage Loss of material retained on ½ x ⅜ in. sieve: no data
Percentage Loss of material retained on ⅜ in. x #4 sieve: no data
Percentage Loss of material retained on 2 in. through 1 1/2 in. sieve: no data
Percentage Loss of material retained on 1 in. through 3/4 in. sieve: no data
Percentage Loss of material retained on 3/4 in. through #4 sieve: no data
Weighted Average Percent Loss of Coarse Aggregate: 0.8 %
Batch Soundness Loss of Coarse Aggregate (2 1/2 in maximum): no data
Batch Soundness Loss of Coarse Aggregate (1 1/2 in maximum): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/18/2014 ✔