Summary for Test 2018-06-25-3-1

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 212354
DEA: 044K8504
EFIS: 0417000378
DIST-CO-RTE-PM04-MRN,MTRN-1-22.8, 22.80
Award Date06/21/2017
Closeout Date12/16/2021
Work DescriptionGiacomini Creek Bridge, Construct sheet pile wall, replace culvert
Location DescriptionROUTE 1, AT POSTMILE 22.8, NEAR BOLINAS, AT 0.52 MILES NORTH OF HORSESHOE HILL RD., MARIN COUNTY SLIPOUT, CONSTRUCT SOLDIER PILE WALL
QA Service Level1 (Verified on 05/01/2017)

Sample Information

Sample Taken Date06/25/2018 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/25/2018
Sample typeQuality Assurance A brief description of the sample1 in ASTM A722
The quantity of what the sample constitutes2 From where was the sample collectedSource
First name of sampler or witnessed byCarolina Last name of sampler or witnessed byMargarito
Title of samplerMETS Rep Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWilliams Form Transportation Laboratory (TL) NumberC647237
Inspector Lot Number from the Transportation Laboratory (TL) FormL73-010-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar Type Rebar Size8
Nut Specification for Threaded BarASTM A 29 System ManufacturerWilliams Form Eng
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)100884585
Nut Heat Number(s)NF15203286, 498335 Bar Lot NumberUnknown
Nut Lot NumberUnknown Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2018-06-25-3
DIME Test ID: 2018-06-25-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2018-07-03

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 06/26/2018
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
11A722 Williams 1\" Threaded Bar & Nut Bar #100884585, Nut #26D9D0.776159543143063554.4A722 Bar & NutFred

General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 6/26/2018