Summary for Test 2018-05-29-4-1
Test performed: ASTM A934-13Project Information
Project Identifiers | Project ID: 210808 DEA: 020E0904 EFIS: 0200000016 |
---|---|
DIST-CO-RTE-PM | 02-SHA-5-R29.3/R31.1,R45.0/R45.8 |
Award Date | 02/03/2016 |
Closeout Date | 10/21/2020 |
Work Description | REPLACE BRIDGE, REALIGN ROADWAY AND SEISMIC RETROFIT |
Location Description | IN SHASTA COUNTY ABT 8 MI N OF SHASTA LAKE CTY AND NEAR LAKEHEAD FRM TURNTABLE BAY O/C TO 0.1 MI N OF O'BRIEN SRRA & FRM 0.4 MI S TO 0.3 MI N OF DOG CREEK BRIDGE. |
QA Service Level | 1 (Verified on 09/23/2015) |
Sample Information
Sample Taken Date | 05/29/2018 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/29/2018 |
Sample type | Quality Assurance | A brief description of the sample | A934 Expoxy Rebar |
The quantity of what the sample constitutes | Lot 1 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | Unknown | Telephone number of sampler | 702 917-2503 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Fletcher Coating Co | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-060-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | SE17104397 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | 8A25B179 8A26A173 | Rebar Coating Specification | ASTM A934 |
Rebar Size (#) | 10 | Rebar Coating Color | Purple |
Rebar Manufacturer | Nucor | Rebar Coater | C180167,C180167 |
Rebar Powder Manufacturer | Fletcher Coating Company | Release Number | Unknown |
Quality Assurance Code | Unknown |
Test Details
DIME Sample ID: 2018-05-29-4
DIME Test ID: 2018-05-29-4-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A934-13: Standard Specification for Epoxy-Coated Prefabricated Steel Reinforcing Bars (Epoxy-Coating)
Test Release Date: 2018-06-18
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 06/07/2018
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 12 mils
Bar # for First Bar: 10
Bar # for Second Bar: 10
First Bar Side 1 mean value: 10.56
First Bar Side 2 mean value: 10.75
Second Bar Side 1 mean value: 10.7
Second Bar Side 2 mean value: 10.4
First Bar Mean: 10.66
Second Bar Mean: 10.55
Total mean value: 10.6
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/11/2018 ✔