Summary for Test 2018-03-26-8-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209384 DEA: 04264094 EFIS: 0400000735 COOP: 042531 |
---|---|
DIST-CO-RTE-PM | 04-,SON-- |
Award Date | 01/21/2016 |
Closeout Date | 06/03/2020 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 06/03/2020) |
Sample Information
Sample Taken Date | 03/26/2018 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2018 |
Sample type | Quality Assurance | A brief description of the sample | Type II/V |
The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | MELVIN | Last name of sampler or witnessed by | DUMLAO |
Title of sampler | ASR | Telephone number of sampler | 5107147638 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Shamrock | Transportation Laboratory (TL) Number | 502 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | San Antonio Creek Bridge |
Structure name | San Antonio Creek Bridge |
Material Information
Material Type | Concrete | The concrete mix design number | 4201A |
---|---|---|---|
The truck number from where the sample was collected | 1440 | The batch plant ticket number from where the sample was collected | 651508 |
Concrete batch plant | 06 | The fabricator/manufacturer designation for the sample | Shamrock |
A detailed description of where the material sample was collected | concrete sample from wheel barrow | Where the material sample would have been placed if not sampled | BARRIER ON BRIDGE |
From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2018-03-26-8
DIME Test ID: 2018-03-26-8-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2018-04-23
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: MM
Date of test: 04/23/2018
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.03 in
Maximum load on cylinder 1: 159240 lb
Maximum load on cylinder 2: 158610 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.56 in^2
Compressive strength of cylinder 1: 5595.2 psi
Compressive strength of cylinder 2: 5553.6 psi
Compressive strength (to nearest 10 psi): 5570 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 2
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 4/23/2018 ✔