Summary for Test 2018-04-02-5-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 212886
DEA: 023H1204
DIST-CO-RTE-PM02-TEH-5-R0.0/R22.4
Award Date01/03/2018
Closeout Date02/06/2019
Work DescriptionCOLD PLANE RAC-O, PLACE RHMA-O, REPLACE AC SURFACING, MBGR
Location DescriptionTEHAMA COUNTY AT AND NEAR CORNING FROM GLENN COUNTY LINE TO 0.3 MILE NORTH OF BRANCH COYOTE CREEK BRIDGE
QA Service Level1 (Verified on 01/08/2019)

Sample Information

Sample Taken Date04/02/2018 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/03/2018
Sample typeAcceptance A brief description of the sampleCombined 3/4-inch Type A Aggregate
The quantity of what the sample constitutesProduction Start Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byAllegretto
Title of samplerLab Tech Telephone number of samplerUnknown
Laboratory sample identification17-07-P07, D77311F Linked DIME Sample ID2018-04-02-3,4
The fabricator/manufacturer/facility nameTullis Inc - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number852090
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0057
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedMathmatically Combined
Where the material sample would have been placed if not sampledDigout HMA Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-04-02-5
DIME Test ID: 2018-04-02-5-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2018-04-06

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): Yes
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 04/06/2018
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 90 %
Cumulative percent passing the 3/8 in. sieve: 68 %
Cumulative percent passing the 1/4 in. sieve: 49 %
Cumulative percent passing the #4 sieve: 43 %
Cumulative percent passing the #8 sieve: 28 %
Cumulative percent passing the #16 sieve: 19 %
Cumulative percent passing the #30 sieve: 13 %
Cumulative percent passing the #50 sieve: 9 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4.9 %
General comments (publicly viewable) (Max 1000 characters): 1/4-inch sieve value is approximate.

Test was verified on 4/6/2018