Summary for Test 2018-03-02-1-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212731 DEA: 07318004 EFIS: 0715000280 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-22.3/28.2 |
Award Date | 11/16/2017 |
Closeout Date | 06/16/2021 |
Work Description | TREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62 |
QA Service Level | 1 (Verified on 03/21/2018) |
Sample Information
Sample Taken Date | 03/02/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/05/2018 |
Sample type | Quality Assurance | A brief description of the sample | Barsplice Double Barrel Zap Screwlok |
The quantity of what the sample constitutes | 3 lots | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russell | Last name of sampler or witnessed by | Lynch |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DRS Rebar Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L96-049-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Nucor |
Coupler Manufacturer | Bar Splice | Intermediate Assembler or Fabricator | |
Rebar Size | #5 | Coupler Model | Barsplice Double Barrel Zap Screwlok |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
Coupler Component Heat/Lot Number(s) | 7048, 80172 | Rebar Heat Number(s) | PL17108760 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2018-03-02-1
DIME Test ID: 2018-03-02-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-04-13
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/05/2018
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 3 | #5/16mm | 0.31 | 29590 | 95450 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/6/2018 ✔