Summary for Test 2018-03-02-1-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212731
DEA: 07318004
EFIS: 0715000280
DIST-CO-RTE-PM07-LA-10-22.3/28.2
Award Date11/16/2017
Closeout Date06/16/2021
Work DescriptionTREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62
QA Service Level1 (Verified on 03/21/2018)

Sample Information

Sample Taken Date03/02/2018 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/05/2018
Sample typeQuality Assurance A brief description of the sampleBarsplice Double Barrel Zap Screwlok
The quantity of what the sample constitutes3 lots From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDRS Rebar Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-049-18 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerBar Splice Intermediate Assembler or Fabricator
Rebar Size#5 Coupler ModelBarsplice Double Barrel Zap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)7048, 80172 Rebar Heat Number(s)PL17108760
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2018-03-02-1
DIME Test ID: 2018-03-02-1-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2018-04-13

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/05/2018
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
133#5/16mm0.312959095450Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/6/2018