Summary for Test 2018-01-29-9-2

Test performed: CTM 202-Oct 2014

Project Information

Project IdentifiersProject ID: 211201
DEA: 074Y8504
EFIS: 0700020042
DIST-CO-RTE-PM07-LA-103-0.9/1.2
Award Date04/13/2016
Closeout Date10/05/2020
Work DescriptionSPOT BLAST, CLEAN AND PAINT EXISTING BRIDGE
Location DescriptionNot set
QA Service Level1 (Verified on 06/30/2017)

Sample Information

Sample Taken Date01/29/2018 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/07/2018
Sample typeAnnual Source Testing A brief description of the sampleFine PCC Aggregate
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byHonesto Last name of sampler or witnessed byCastillo
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification18-0021 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameVulcan San Bernardino Transportation Laboratory (TL) NumberC914521C
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0012::SAN BERNARDINO
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberNot set
Sublot numberNot set Aggregate Mix NumberNot set
HMA PayNo

Test Details

DIME Sample ID: 2018-01-29-9
DIME Test ID: 2018-01-29-9-2
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-Oct 2014: Method of Test for Determining Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2018-03-28

Test Results


What size aggregate is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: Phillip Montes
Date of test: 03/01/2018
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 95 %
Cumulative percent passing the #8 sieve: 81 %
Cumulative percent passing the #16 sieve: 66 %
Cumulative percent passing the #30 sieve: 43 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 4 %
Cumulative percent passing the #200 sieve: 1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/28/2018