Summary for Test 2018-01-09-7-3

Test performed: ASTM D412-06a-re13

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date01/09/2018 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/10/2018
Sample typeQuality Assurance A brief description of the sampleJoint Seal
The quantity of what the sample constitutes1 From where was the sample collectedManufacturer
First name of sampler or witnessed byDavid Last name of sampler or witnessed bySimon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameWatson Bowman Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM2 - Type B Elastomeric Joint Seal Mfg. Lot Number(s)0118103
Manufacturer(s)Watsom Bowman Temperature72
Humidity50 CommentsUnknown
Joint Seal Size2.75

Test Details

DIME Sample ID: 2018-01-09-7
DIME Test ID: 2018-01-09-7-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM D412-06a-re13: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension
Test Release Date: 2018-01-30

Test Results


Number of specimens tested: 3
Unit of the Ultimate Tensile Values: psi
Input Type: Calculated
Tester's full name: Brian
Date of test: 01/17/2018
UTM: 2KIP
Humidity: 50 %
Temperature: 72 F
Sample 1 Median Thickness: 0.08 in
Sample 1 Thickness all Within 0.003 inch?: Yes
Sample 1 Ultimate Tensile: 2400 lbf?in/in?
Sample 1 Elongation (350% Min): Pass
Sample 2 Median Thickness: 0.078 in
Sample 2 Thickness all Within 0.003 inch?: Yes
Sample 2 Ultimate Tensile: 2359 lbf?in/in?
Sample 2 Elongation (350% Min): Pass
Sample 3 Median Thickness: 0.072 in
Sample 3 Thickness all Within 0.003 inch?: Yes
Sample 3 Ultimate Tensile: 2444.4 lbf?in/in?
Sample 3 Elongation (350% Min): Pass
Median of the Ultimate Tensile Values: 2400 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point File
Test graph for Sample 1

Source: Partner Data Point File
Test graph for Sample 2

Source: Partner Data Point File
Test graph for Sample 3

Test was verified on 1/23/2018