Summary for Test 2018-01-09-1-3
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212716 DEA: 101F7904 EFIS: 1016000114 MINOR: 10A1874 |
---|---|
DIST-CO-RTE-PM | 10-SJ-99-5.8 |
Award Date | Not set |
Closeout Date | 12/29/2022 |
Work Description | Install Bridge Mounted Sign |
Location Description | Not set |
QA Service Level | 1 (Verified on 12/20/2018) |
Sample Information
Sample Taken Date | 01/09/2018 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 01/11/2018 |
Sample type | Quality Assurance | A brief description of the sample | Bridge mount sign hardware |
The quantity of what the sample constitutes | 22 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ken | Last name of sampler or witnessed by | Varela |
Title of sampler | Associate Steel Inspector | Telephone number of sampler | 562-440-7716 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Nucor | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L08-004-18 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 061217A |
---|---|---|---|
Heat Number(s) | 100786273 | Nut Mfg. Lot Number(s) | 365483B |
Washer Mfg. Lot Number(s) | D1287 | Bolt Specification | A325 |
Bolt Length(s) | 2-1/2" | Nut Specification | A563 |
Washer Specification | F436 | Finish | Mech Galv |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | 387302A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2018-01-09-1
DIME Test ID: 2018-01-09-1-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2018-01-18
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 01/11/2018
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 387302A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 U USA
Size: .75 in
Bolt Length: 2.5 in
Measurement Average: 3.68 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/11/2018 ✔