Summary for Test 2017-04-07-19-4
Test performed: AASHTO T304-11Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 04/07/2017 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/07/2017 |
Sample type | Quality Control | A brief description of the sample | Combined Half Inch Type A Untreated Virgin |
The quantity of what the sample constitutes | JMF | From where was the sample collected | Source |
First name of sampler or witnessed by | a | Last name of sampler or witnessed by | a |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | JMF 17-01-S1 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Hat Creek - Shaw Pit Facility | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-25-0008 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Combined Half Inch Type A Untreated Virgin | The fabricator/manufacturer designation for the sample | One Half inch Type A - Untreated Virgin |
The plant number | Unknown | A detailed description of where the material sample was collected | Batched in Lab |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | 16-1278 72 | Lot number | Not set |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2017-04-07-19
DIME Test ID: 2017-04-07-19-4
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2017-12-13
Test Results
What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 04/07/2017
Bulk dry specific gravity: 2.592
Average uncompacted voids: 46 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/13/2017 ✔