Summary for Test 2017-11-09-7-19
Test performed: ASTM E18-15Project Information
Project Identifiers | Project ID: 3807 DEA: 07121844 EFIS: 0700000117 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-42.8/47.3 |
Award Date | 12/06/2010 |
Closeout Date | 06/30/2021 |
Work Description | CONSTRUCT HOV LANES, RETAINING WALLS AND SOUND WALLS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES, GLENDALE, AND BURBANK FROM ROUTE 5/134 SEPARATION TO MAGNOLIA BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 02/23/2012) |
Sample Information
Sample Taken Date | 11/09/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/28/2017 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 A325 |
The quantity of what the sample constitutes | 9 | From where was the sample collected | Source |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | McLaurin |
Title of sampler | QA Inspector | Telephone number of sampler | 6616185971 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | St Louis Screw Bolt | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L67-245-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0095156 |
---|---|---|---|
Heat Number(s) | NF16203584 | Nut Mfg. Lot Number(s) | 24445-166292 |
Washer Mfg. Lot Number(s) | D4420 | Bolt Specification | A325 |
Bolt Length(s) | 2" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | Mechanical Galvanizing |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | BM0477 |
Rocap Test Requirement(s) | Lubricant Requirements(s) | Blue |
Test Details
DIME Sample ID: 2017-11-09-7
DIME Test ID: 2017-11-09-7-19
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2017-12-12
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 11/30/2017
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: D4420
Finish Coating: ASTM B695 - Mech Galv
Product Markings: P F436
Size: .75 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 40.15
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/5/2017 ✔