Summary for Test 2017-10-24-1-1
Test performed: ASTM A775-07b-re14Project Information
Project Identifiers | Project ID: 212566 DEA: 120Q8604 EFIS: 1217000117 |
---|---|
DIST-CO-RTE-PM | 12-ORA-57-11.0/19.6 |
Award Date | 08/08/2017 |
Closeout Date | 07/02/2021 |
Work Description | SLAB REPLACEMENT (RSC), GRIND & GROOVE CONC PVMT, RHMA-G PVMT |
Location Description | ORANGE COUNTY IN ORANGE, ANAHEIM, PLACENTIA, AND FULLERTON FROM 0.2 MILE SOUTH OF CHAPMAN AVENUE UNDERCROSSING TO ASSOCIATED ROAD UNDERCROSSING |
QA Service Level | 1 (Verified on 10/25/2017) |
Sample Information
Sample Taken Date | 10/24/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2017 |
Sample type | Recertification | A brief description of the sample | Epoxy Coated Dowels |
The quantity of what the sample constitutes | 30 shipments | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Subramony | Last name of sampler or witnessed by | Krishnamoorthy |
Title of sampler | Inspector | Telephone number of sampler | 951-436-6777 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | J C Supply - Manufacturing | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L88-026-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | Dowel Heat PL 16208488 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | Rebar Coating Specification | ASTM A775 | |
Rebar Size (#) | Dowel 1.5"X 18" | Rebar Coating Color | Green |
Rebar Manufacturer | Dowel,Nucor | Rebar Coater | JC Supply And Manufacturing |
Rebar Powder Manufacturer | Valspar | Release Number | Unknown |
Quality Assurance Code | Unknown |
Test Details
DIME Sample ID: 2017-10-24-1
DIME Test ID: 2017-10-24-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2017-11-07
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 10/31/2017
Lower spec. limit LSL: 7
Upper spec. limit USL: 40
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 9.57
First Bar Side 2 mean value: 11.89
Second Bar Side 1 mean value: 10
Second Bar Side 2 mean value: 8.93
First Bar Mean: 10.73
Second Bar Mean: 9.47
Total mean value: 10.1
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/31/2017 ✔