Summary for Test 2017-10-24-9-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212143
DEA: 101F1604
EFIS: 1016000107
DIST-CO-RTE-PM10-MER-33,5-R16.6
Award Date05/01/2017
Closeout Date03/29/2018
Work DescriptionBRIDGE REPAIR
Location DescriptionMERCED COUNTY IN SANTA NELLA AT ROUTE 33/5 SEPARATION
QA Service Level1 (Verified on 07/20/2017)

Sample Information

Sample Taken Date10/24/2017 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/24/2017
Sample typeQuality Assurance A brief description of the sample6, and 8 size couplers
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byYe Last name of sampler or witnessed byYang
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Dayton Transportation Laboratory (TL) NumberC06-001470
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#6, #8 Coupler ModelBar-Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)MM16106573, A152318, A150815 Rebar Heat Number(s)SE16104894, SE17100041
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-10-24-9
DIME Test ID: 2017-10-24-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-11-03

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 10/26/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#6/19mm0.4404034591693Service SpliceFred

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 10/27/2017