Summary for Test 2017-09-13-13-3
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211513 DEA: 120M4904 EFIS: 1212000090 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-1.2/2.2 |
Award Date | 09/20/2016 |
Closeout Date | 01/09/2020 |
Work Description | WIDEN FWY AND BRIDGE AND CONSTRUCT RW, SOUND WALL, AND CONC BARRIERS. |
Location Description | ORANGE COUNTY IN SAN CLEMENTE FROM 0.1 MILE NORTH OF AVENIDA MENDOCINO OVERCROSSING TO 0.2 MILE SOUTH OF AVENIDA PRESIDIO UNDERCROSSING |
QA Service Level | 1 (Verified on 11/03/2016) |
Sample Information
Sample Taken Date | 09/13/2017 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/15/2017 |
Sample type | Quality Assurance | A brief description of the sample | HRC 500 510 Couplers |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Braidy | Last name of sampler or witnessed by | Fernandez |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HRC | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | CMC |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 8 | Coupler Model | HRC 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | HRC 500 A162514 HRC 510 177275 | Rebar Heat Number(s) | 4060211, 4060214 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-09-13-13
DIME Test ID: 2017-09-13-13-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-09-26
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/18/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 3 | 3 | #8/25mm | 0.79 | 0 | 73357 | 92857 | OK Necking | Fred |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 9/19/2017 ✔