Summary for Test 2017-09-08-2-6

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211778
DEA: 04235654
EFIS: 0400000680
DIST-CO-RTE-PM04-SM-101,114-1.3/2.5,5.0/5.3
Award Date02/10/2017
Closeout Date01/08/2020
Work DescriptionRECONSTRUCT INTERCHANGE
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATIONS ON ROUTE 101 FROM 0.4 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.6 MILE SOUTH OF HENDERSON UNDERPASS AND ON ROUTE 114 FROM WILLOW ROAD SEPARATION TO NEWBRIDGE STREET
QA Service Level1 (Verified on 10/24/2016)

Sample Information

Sample Taken Date09/08/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testingNot set
Sample typeQuality Assurance A brief description of the sampleResistance welded hoops
The quantity of what the sample constitutes324 From where was the sample collectedFabricator
First name of sampler or witnessed byRussell Last name of sampler or witnessed byLynch
Title of samplerQAI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Rebar Transportation Laboratory (TL) NumberC939712
Inspector Lot Number from the Transportation Laboratory (TL) FormL96-150-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4067850
Hoop Manufacturer Lot Number(s)Lot 1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop6'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyCMC Rebar (Etiwanda) Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-09-08-2
DIME Test ID: 2017-09-08-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-09-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 09/13/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
132#7/22mm0.65782096370Bar BrokeFred

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 9/14/2017