Summary for Test 2017-07-26-1-10
Test performed: ASTM F606-14Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/26/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2017 |
Sample type | Verification | A brief description of the sample | stock hardware for anchor bolt assemblies |
The quantity of what the sample constitutes | 5 pcs ea | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 8016692984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | UIS | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-110-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | n/a |
---|---|---|---|
Heat Number(s) | 155816,156042,155706,DL15106136,627586,75063411,166726,62141302 | Nut Mfg. Lot Number(s) | DDTB, DDTN, DDSM, 24056-75063411 |
Washer Mfg. Lot Number(s) | D3390 | Bolt Specification | A449 HDG |
Bolt Length(s) | 5/8"x12",7/8"x18",7/8"x17",7/8"x16",7/8"x15" | Nut Specification | A563-DH HDG,plain |
Washer Specification | F436 | Finish | HDG,plain |
Diameter/Size | 21/2" nut's,5/8x12 bolt,5/8"washer,5/8" nut,7 | Bolt Mfg. Lot Number | 29346,29870,28042-B,29391,29052 |
Rocap Test Requirement(s) | not required | Lubricant Requirements(s) | none |
Test Details
DIME Sample ID: 2017-07-26-1
DIME Test ID: 2017-07-26-1-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Hex Cap Screws)
Test Release Date: 2017-08-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 08/07/2017
UTM: 400KIP
Temperature: 72
Num | Sample | Size | Area (in^2) | Peak Load (lbf) | Peak Load (kN) | Tensile Strength (psi) | Stress at Offset (psi) | Load at Offset (lbf) | Comments |
---|---|---|---|---|---|---|---|---|---|
1 | 4A | A449 5/8\" x 12\" | 0.226 | 2 | 8 | 9 | 0 | 0 |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest was verified on 8/9/2017 ✔