Summary for Test 2017-08-01-4-3
Test performed: ASTM A775-07b-re14Project Information
Project Identifiers | Project ID: 208682 DEA: 083401U4 EFIS: 0800000609 |
---|---|
DIST-CO-RTE-PM | 08-SBD-138,138-6.2/6.4,2.3/R15.2 |
Award Date | 09/10/2014 |
Closeout Date | 06/23/2021 |
Work Description | WIDEN TO 4 LNS FR BEEKLEY RD TO JCT 15, ADD 1 LN EB FR PHELAN RD TO |
Location Description | SAN BERNARDINO COUNTY ON ROUTE 138 NEAR PHELAN FROM 0.6 MILE WEST OF PHELAN ROAD TO THE JUNCTION OF ROUTE 15 AND ON ROUTE 2 FROM 0.1 MILE NORTH OF WILD HORSE CANYON ROAD TO ROUTE 138 |
QA Service Level | 1 (Verified on 03/11/2013) |
Sample Information
Sample Taken Date | 08/01/2017 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/02/2017 |
Sample type | Verification | A brief description of the sample | 5, 6, 8, A775 epoxy coated rebar |
The quantity of what the sample constitutes | 1 truck load | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | David | Last name of sampler or witnessed by | Flygare |
Title of sampler | CA METS QA Inspector | Telephone number of sampler | 801-669-2984 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Western Coating | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B76-121-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM7 - Epoxy Coated Rebar | Rebar Heat Number(s) | 4065349, PL17205214, PL17103455, PL17203474 |
---|---|---|---|
Rebar Epoxy Batch Number(s) | 7696024903, TD95852NA | Rebar Coating Specification | ASTM A775 |
Rebar Size (#) | 5, 6, 8 | Rebar Coating Color | Green |
Rebar Manufacturer | CMC,Nucor | Rebar Coater | Western Coating |
Rebar Powder Manufacturer | Valspar,Axalta | Release Number | 36368 |
Quality Assurance Code | Unknown |
Test Details
DIME Sample ID: 2017-08-01-4
DIME Test ID: 2017-08-01-4-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A775-07b-re14: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)
Test Release Date: 2017-08-14
Test Results
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 08/04/2017
Lower spec. limit LSL: 7 mils
Upper spec. limit USL: 16 mils
Bar # for First Bar: no data
Bar # for Second Bar: no data
First Bar Side 1 mean value: 8.188 mils
First Bar Side 2 mean value: 8.853 mils
Second Bar Side 1 mean value: 8.737 mils
Second Bar Side 2 mean value: 9.197 mils
First Bar Mean: 8.52 mils
Second Bar Mean: 8.97 mils
Total mean value: 8.74 mils
General comments (publicly viewable) (Max 1000 characters): #6 Rebar
Test was verified on 8/7/2017 ✔