Summary for Test 2013-10-30-10305319-5
Test performed: CTM 227-June 2012Project Information
Project Identifiers | Project ID: 7757 DEA: 07252614 EFIS: 0700021271 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-C43.9/C46.4 |
Award Date | 12/12/2012 |
Closeout Date | 06/02/2015 |
Work Description | REPLACE CONCRETE SLABS WITH PRECAST CONCRETE PANELS. |
Location Description | LOS ANGELES COUNTY IN AND NEAR LOS ANGELES FROM SAN FERNANDO ROAD OVERHEAD TO 0.2 MILE SOUTH OF WELDON CANYON OVERCROSSING |
QA Service Level | 1 (Verified on 11/12/2012) |
Sample Information
Sample Taken Date | 10/30/2013 | Sample Unique Key | 10305319 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/31/2013 |
Sample type | Annual Source Testing | A brief description of the sample | 3/8 Crushed PCC Aggregates |
The quantity of what the sample constitutes | 8 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Jeff | Last name of sampler or witnessed by | Lopez |
Title of sampler | Quality Control Manager | Telephone number of sampler | (951) 634-2002 |
Laboratory sample identification | 3260B | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Cemex Lytle Creek | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-36-0040::LYTLE CREEK |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Not set | The fabricator/manufacturer designation for the sample | Not set |
The plant number | Not set | A detailed description of where the material sample was collected | Conveyer Belt |
Where the material sample would have been placed if not sampled | Not set | Primary Aggregate Nominal Size | 3/8 inch |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Combined Gradation Report Information
Combined Gradation Report Id | Bin Index | Dime Test Id |
---|---|---|
No assigned tests for this sample. |
Test Details
DIME Sample ID: 2013-10-30-10305319
DIME Test ID: 2013-10-30-10305319-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 227-June 2012: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2014-02-28
Test Results
Describe the gradation of the aggregate:: Mix of sizes - max 1.5 in.
Input Type: Calculated
Tester's full name: Nader Rashidi
Date of test: 11/14/2013
Cleanness value (11/2 in. maximum aggregate mix): 79
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/28/2014 ✔