Summary for Test 2017-07-18-17-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 211588 DEA: 030F3104 EFIS: 0300000078 |
---|---|
DIST-CO-RTE-PM | 03-ED-49-23.6/24.5 |
Award Date | 12/12/2016 |
Closeout Date | 01/08/2019 |
Work Description | REPLACE BRIDGE. |
Location Description | EL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD |
QA Service Level | 1 (Verified on 10/19/2016) |
Sample Information
Sample Taken Date | 07/18/2017 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/20/2017 |
Sample type | Quality Assurance | A brief description of the sample | 14 Rebar Couplers |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Glen | Last name of sampler or witnessed by | Wheeler |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | HRC Gerdau | Transportation Laboratory (TL) Number | C543601 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Service | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Manufacturer | Gerdau |
Coupler Manufacturer | HRC | Intermediate Assembler or Fabricator | Unknown |
Rebar Size | 14 | Coupler Model | HRC 500-510 |
Coating Standards | Uncoated | Shape of Rebar | Straight |
Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
Coupler Component Heat/Lot Number(s) | ABC123 | Rebar Heat Number(s) | 65023793 02 |
Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-07-18-17
DIME Test ID: 2017-07-18-17-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-07-28
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 07/20/2017
UTM: 2000KIP
Halo ID: Small
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Slip (inch) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #14/43mm | 2.25 | 0 | 215408 | 95737 | Service Splice | Brian |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 7/21/2017 ✔