Summary for Test 2017-07-05-2-22
Test performed: ASTM E18-15Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/05/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/14/2017 |
Sample type | Quality Assurance | A brief description of the sample | Anchor Bolt Assemblies |
The quantity of what the sample constitutes | 93 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | William | Last name of sampler or witnessed by | Clifford |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 5103253065 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | AM Nut and Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L78-024-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 3064792 | Nut Mfg. Lot Number(s) | 20910-6213727605 |
Washer Mfg. Lot Number(s) | 299833 | Bolt Specification | ASTM F1554 Gr55 |
Bolt Length(s) | 42" | Nut Specification | A194 |
Washer Specification | F436 | Finish | Hot Dip Galvanized |
Diameter/Size | 1 1/4" | Bolt Mfg. Lot Number | 3064792 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-07-05-2
DIME Test ID: 2017-07-05-2-22
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E18-15: Standard Test Methods for Rockwell Hardness of Metallic Materials (Hardness)
Test Release Date: 2017-07-31
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/20/2017
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 299883
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: WS
Size: 1.25 in
Bolt Length: no data
Hardness Reading Scale: C Scale
Spacing: Ok
Hardness Reading Average: 36.6
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/24/2017 ✔