Summary for Test 2013-12-31-12302467-2
Test performed: ASTM C136-06Project Information
Project Identifiers | Project ID: 10016 DEA: 06342524 EFIS: 0600000381 |
---|---|
DIST-CO-RTE-PM | 06-FRE-180-R71.8/74.5 |
Award Date | 04/23/2013 |
Closeout Date | 10/19/2020 |
Work Description | NEW EXPRESS HIGHWAY |
Location Description | FRESNO COUNTY ABOUT 6.3 MILES EAST OF FRESNO FROM 0.6 MILE WEST OF QUALITY AVENUE TO 0.2 MILE WEST OF SMITH AVENUE |
QA Service Level | 1 (Verified on 07/23/2013) |
Sample Information
Sample Taken Date | 12/31/2013 | Sample Unique Key | 12302467 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/31/2013 |
Sample type | Quality Control | A brief description of the sample | Sand |
The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Allen | Last name of sampler or witnessed by | Oliver |
Title of sampler | Plant Technician | Telephone number of sampler | (559) 292-2188 |
Laboratory sample identification | 2013-12-31-12-30 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Builders Concrete Ready Mix Plant Sanger | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-10-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Sand | The fabricator/manufacturer designation for the sample | Plant |
The plant number | 1111 | A detailed description of where the material sample was collected | Stockpile |
Where the material sample would have been placed if not sampled | Stockpile | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Test Details
DIME Sample ID: 2013-12-31-12302467
DIME Test ID: 2013-12-31-12302467-2
Testing Lab: Trinity Engineering Laboratories, Incorporated - Fresno
Test Method: ASTM C136-06: Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2014-02-18
Test Results
What type of gradation is being tested?: Fine Aggregate
Input Type: Calculated
Tester's full name: Allen Oliver
Date of test: 12/31/2013
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 99 %
Cumulative percent passing the #8 sieve: 85 %
Cumulative percent passing the #16 sieve: 70 %
Cumulative percent passing the #30 sieve: 44 %
Cumulative percent passing the #50 sieve: 17 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 2/18/2014 ✔