Summary for Test 2017-07-11-1-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209146 DEA: 06471504 EFIS: 0600000464 COOP: 061549 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-39.6/41.3 |
Award Date | 02/24/2017 |
Closeout Date | 03/03/2020 |
Work Description | RECONSTRUCT INTERCHANGE WITH NEW PUMPING PLANT. |
Location Description | TULARE COUNTY AT GOSHEN FROM 0.9 MILE NORTH OF ROUTE 99/198 WEST SEPARATION TO 0.2 MILE NORTH OF NORTH GOSHEN OVERHEAD |
QA Service Level | 1 (Verified on 10/08/2013) |
Sample Information
Sample Taken Date | 07/11/2017 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/12/2017 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 12 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Greg | Last name of sampler or witnessed by | Johnston |
Title of sampler | QA | Telephone number of sampler | 9165247768 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | CMC Rbar | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L5314517 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4066804 4067060 |
Hoop Manufacturer Lot Number(s) | 1, 3 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6, 7 |
Diameter of Hoop | 3' 6", 3' 8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Rebar |
Welding Company | CMC Rebar (Etiwanda) | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-07-11-1
DIME Test ID: 2017-07-11-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-07-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 07/13/2017
UTM: 400KIP
Temperature: 72 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 1 | #6/19mm | 0.44 | 42050 | 95570 | Bar Broke | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample