Summary for Test 2017-06-28-2-10
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 211968 DEA: 101F0804 EFIS: 1016000116 |
---|---|
DIST-CO-RTE-PM | 10-SJ-4,26-19.75,1.1 |
Award Date | 03/15/2017 |
Closeout Date | 04/05/2018 |
Work Description | HEAT STRAIGHTENING EXISTING STEEL GIRDERS. |
Location Description | SAN JOAQUIN COUNTY IN STOCKTON ON ROUTE 4 AT FARMINGTON ROAD OVERCROSSING AND ON ROUTE 26 AT ROUTE 26/99 SEPARATION. |
QA Service Level | 1 (Verified on 05/16/2017) |
Sample Information
Sample Taken Date | 06/28/2017 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 06/30/2017 |
Sample type | Acceptance | A brief description of the sample | ASTM A325 7/8x2 HDG |
The quantity of what the sample constitutes | 35.24 | From where was the sample collected | Source |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
Title of sampler | QA | Telephone number of sampler | 9167993391 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Portland Bolt | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-356-17 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | L1412224,L1412225 |
---|---|---|---|
Heat Number(s) | NF14101295,NF14201806 | Nut Mfg. Lot Number(s) | 22225-6213796603 |
Washer Mfg. Lot Number(s) | D2180 | Bolt Specification | A325 |
Bolt Length(s) | 2",2.25" | Nut Specification | A563 DH |
Washer Specification | F436 | Finish | HDG |
Diameter/Size | 7/8x2,7/8"x2.25 | Bolt Mfg. Lot Number | 349548A,344955A |
Rocap Test Requirement(s) | Yes | Lubricant Requirements(s) | Yes |
Test Details
DIME Sample ID: 2017-06-28-2
DIME Test ID: 2017-06-28-2-10
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-07-13
Test Results
Input Type: Calculated
Tester's full name: Brian Ewing
Date of test: 07/06/2017
Sample No.: 1B
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 22225-6213796603
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: U DH
Size: .875 in
Bolt Length: no data
Measurement Average: 4.23 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/6/2017 ✔