Summary for Test 2017-06-06-7-41
Test performed: ASTM F606-14aProject Information
Project Identifiers | Project ID: 8196 DEA: 59912684 |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | |
Location Description | |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/06/2017 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/09/2017 |
Sample type | Quality Assurance | A brief description of the sample | F1554 anchor rods, A325 Bolt Assembly |
The quantity of what the sample constitutes | 27 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Churchill |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Universal Industrial Sales Unytite, Prestige, | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L0204017 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | TT0085815, TT0085814 |
---|---|---|---|
Heat Number(s) | PL16102621 | Nut Mfg. Lot Number(s) | 23501-166333, 23220-6214073903 |
Washer Mfg. Lot Number(s) | D0217, D2048, Z1B-A | Bolt Specification | A325, F1554 |
Bolt Length(s) | 5", 2.75", 3'-4" | Nut Specification | A563 |
Washer Specification | F436, F959 | Finish | MG, HDG |
Diameter/Size | 1.5", 0.625", 2.5" | Bolt Mfg. Lot Number | 22640-75061539, BM0107 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2017-06-06-7
DIME Test ID: 2017-06-06-7-41
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-14a: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2017-06-21
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 06/14/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | L0204017 | 1 1/2\" | 215180 | 957.16 | A563 MG | Arnold |
General comments (publicly viewable) (Max 1000 characters): A563 MG
Test Graph
Source: Partner Data Point FileTest was verified on 6/14/2017 ✔