Summary for Test 2024-04-11-65-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994325 DEA: 044J4904 EFIS: 0415000356 |
---|---|
DIST-CO-RTE-PM | 04-ALA-13-6.7/7.2 |
Award Date | 01/09/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY. |
Location Description | ALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
Sample Taken Date | 04/11/2024 | Sample Unique Key | 65 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/11/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G Mix |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Lab Technician | Telephone number of sampler | 7072999133 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | DeSilva Gates Sunol | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | MD 6668 |
Test Details
DIME Sample ID: 2024-04-11-65
DIME Test ID: 2024-04-11-65-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-04-24
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 04/17/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1780.6 g
Mass Loss: 152.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.90 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.17 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.51 %
General comments (publicly viewable) (Max 1000 characters): Burn # 1
Test was verified on 4/24/2024 ✔