Summary for Test 2024-04-11-65-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994325
DEA: 044J4904
EFIS: 0415000356
DIST-CO-RTE-PM04-ALA-13-6.7/7.2
Award Date01/09/2023
Closeout DateNot set
Work DescriptionCONSTRUCT CONCRETE BARRIERS AND BARRIER SLAB, COLD PLANE AND OVERLAY.
Location DescriptionALAMEDA COUNTY IN OAKLAND FROM 0.2 MILE NORTH OF LINCOLN AVENUE OVERCROSSING TO 0.2 MILE SOUTH OF PARK BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 10/14/2022)

Sample Information

Sample Taken Date04/11/2024 Sample Unique Key65
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/11/2024
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-G Mix
The quantity of what the sample constitutes750 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byNick Last name of sampler or witnessed byHall
Title of samplerLab Technician Telephone number of sampler7072999133
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDeSilva Gates Sunol Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix NumberMD 6668

Test Details

DIME Sample ID: 2024-04-11-65
DIME Test ID: 2024-04-11-65-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-04-24

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Nicholas Hall
Date of test: 04/17/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1737.3 g
Mass Loss: 152.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.90 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.77 %
General comments (publicly viewable) (Max 1000 characters): Burn #2

Test was verified on 4/24/2024