Summary for Test 2024-04-11-41-10
Test performed: AASHTO T30-19Project Information
Project Identifiers | Project ID: 993529 DEA: 11430514 EFIS: 1119000008 |
---|---|
DIST-CO-RTE-PM | 11-SD-15-R31.3/R37.1 |
Award Date | 05/27/2022 |
Closeout Date | Not set |
Work Description | CRCP, FIBER OPTIC CABLE, AND HMA. |
Location Description | SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 02/07/2022) |
Sample Information
Sample Taken Date | 04/11/2024 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/12/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA PSU |
The quantity of what the sample constitutes | 3 Bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 6638-PSU | Linked DIME Sample ID | 2024-04-11-40 |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-04-11-41
DIME Test ID: 2024-04-11-41-10
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T30-19: Standard Method of Test for Mechanical Analysis of Extracted Aggregate (Mechanical Analysis)
Test Release Date: 2024-04-22
Test Results
Does this test use 1/4 sieve?: No
Is an aggregate correction factor used?: No
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 04/18/2024
Cumulative Mass Retained | Cumulative Percent Passing | |||||
---|---|---|---|---|---|---|
1446.1 grams | ||||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
0.0 grams | 100 % | |||||
11.0 grams | 99 % | |||||
261.0 grams | 82 % | |||||
516.0 grams | 64 % | |||||
737.0 grams | 49 % | |||||
925.0 grams | 36 % | |||||
1093.0 grams | 24 % | |||||
1214.0 grams | 16 % | |||||
1293.0 grams | 10.6 % |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/22/2024 ✔