Summary for Test 2023-08-11-39-5
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 993806 DEA: 07330504 EFIS: 0716000214 |
---|---|
DIST-CO-RTE-PM | 07-LA-710-R15.1/21.9 |
Award Date | 08/02/2022 |
Closeout Date | Not set |
Work Description | INSTALL HIGHWAY PLANTING AND PLACE MINOR CONCRETE. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.2 MILE NORTH OF ROSECRANS AVENUE TO 0.1 MILE SOUTH OF ATLANTIC AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 05/11/2022) |
Sample Information
Sample Taken Date | 08/11/2023 | Sample Unique Key | 39 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/16/2023 |
Sample type | Production Start-Up | A brief description of the sample | 3/4" HMA-A-SP R15 0.5%" LAS |
The quantity of what the sample constitutes | 20 BOXES OF HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Baher | Last name of sampler or witnessed by | Fakhoury |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0407A-23 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Irwindale | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 220831A IRW LTR |
Test Details
DIME Sample ID: 2023-08-11-39
DIME Test ID: 2023-08-11-39-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-04-22
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Antonio Torres
Date of test: 02/22/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7352.9 grams
Mass of oven-dry sample in air for Sample 1: 2573.9 grams
Mass of container filled with the sample and water for Sample 1: 8887.3 grams
Temperature of Water: 25 °F
Specific Gravity for Sample 1: 2.476
Theoretical maximum density at 25°C (77°F): 2468.8 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/22/2024 ✔