Summary for Test 2024-04-02-43-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 214486
DEA: 080K1224
EFIS: 0815000244
DIST-CO-RTE-PM08-SBD-15-R28.6/37.5
Award DateNot set
Closeout DateNot set
Work DescriptionREHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT
Location DescriptionSAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date04/02/2024 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/02/2024
Sample typeAcceptance A brief description of the sample1'' HMA Aggregate
The quantity of what the sample constitutes1 Bag of Coldfeed Aggregate From where was the sample collectedManufacturer
First name of sampler or witnessed byRigoberto Last name of sampler or witnessed byA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBlue Diamond-Victorville Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0022
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number300222-CPC R25 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-04-02-43
DIME Test ID: 2024-04-02-43-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-04-18

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Nathan Ogbasellasie
Date of test: 04/05/2024
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 88 %
Cumulative percent passing the 1/2 in. sieve: 78 %
Cumulative percent passing the 3/8 in. sieve: 72 %
Cumulative percent passing the #4 sieve: 55 %
Cumulative percent passing the #8 sieve: 44 %
Cumulative percent passing the #16 sieve: 33 %
Cumulative percent passing the #30 sieve: 22 %
Cumulative percent passing the #50 sieve: 13 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/18/2024