Summary for Test 2024-04-17-19-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994397 DEA: 073393U4 EFIS: 0722000031 |
---|---|
DIST-CO-RTE-PM | 07-LA-605-R11.4/R19.5 |
Award Date | 02/14/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT DPPIA DEVICES AND MODIFY LIGHTING SYSTEMS. |
Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF SLAUSON AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF VALLEY BOULEVARD UNDERCROSSING |
QA Service Level | 1 (Verified on 07/13/2023) |
Sample Information
Sample Taken Date | 04/17/2024 | Sample Unique Key | 19 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/17/2024 |
Sample type | Quality Assurance | A brief description of the sample | Native Material |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Alberto | Last name of sampler or witnessed by | Pineda-Gonzalez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 24-0665 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | CTM 231 Test Holes | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-04-17-19
DIME Test ID: 2024-04-17-19-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-18
Test Results
Method Type:: Direct Read
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: Alberto Pineda-Gonzalez
Date of test: 04/17/2024
Gage No.: no data
Test No.: no data
Nuclear By: no data
Non-Bias Plan No.: no data
Depth: no data
Material No.: no data
Material Type: no data
Impact By: no data
Standard Count Density: 1890 g/cc
Count or Density 1: 1072 g/cc
Count or Density 2: 1038 g/cc
Count or Density 3: 1014 g/cc
Standard Count Moisture: 611 g/cc
Moisture Count 1: 132 g/cc
Moisture Count 2: 130 g/cc
Moisture Count 3: 118 g/cc
Sum of Count or Density: 3124.00 g/cc
Average of Count or Density: 1041.33 g/cc
Sum of Moisture Count: 380.00 g/cc
Average of Moisture Count: 126.67 g/cc
Calculated Percent Relative Compaction: 96.4 %
Reported Percent Relative Compaction: 96 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/18/2024 ✔