Summary for Test 2024-04-01-31-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 993387
DEA: 07323404
EFIS: 0716000064
DIST-CO-RTE-PM07-LA-5-R59.5/R67.9
Award DateNot set
Closeout DateNot set
Work DescriptionPLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT.
Location DescriptionLOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date04/01/2024 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/01/2024
Sample typeQuality Assurance A brief description of the sample6"x12" cylinders for RSC
The quantity of what the sample constitutes10 cubic yards From where was the sample collectedJob Site
First name of sampler or witnessed byAleksey Last name of sampler or witnessed bySouglobov
Title of sampler Telephone number of sampler
Laboratory sample identification24-0550 Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-24-CTS-368
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-04-01-31
DIME Test ID: 2024-04-01-31-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-04-17

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 04/11/2024
Identification number: 24-0550
Width of specimen: 6 inch
Width of specimen 2: 6.0625 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6.0625 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 6727 lb
Maximum load applied 2: 7005 lb
Maximum load applied 3: 7143 lb
Curing history and apparent moisture condition of the specimen: Sand
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 590 psi
Modulus of rupture 2: 590 psi
Modulus of rupture 3: 620 psi
Modulus of rupture average: 600 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/17/2024