Summary for Test 2024-04-10-20-7
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 994828 DEA: 043Y4104 EFIS: 0423000232 |
---|---|
DIST-CO-RTE-PM | 04-CC,SM-680-25.04/25.46, VAR/VAR |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Paint removal and non-destructive testing (NDT) on butt weld connections on T1 type steel in fracture critical members of three distinct existing toll bridge. |
Location Description | Carquinez Bridge Overhead (Br. No. 23-0015R), Benicia-Martinez Bridge Overhead (Br. No. 28-0153L), and San Mateo-Hayward Bridge (Br. No. 35-0054). County = SM,CC,SOL. Route = 680,80,92. |
QA Service Level | 1 (Verified on 05/16/2023) |
Sample Information
Sample Taken Date | 04/10/2024 | Sample Unique Key | 20 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/12/2024 |
Sample type | Quality Assurance | A brief description of the sample | A325 3/4X31/2 |
The quantity of what the sample constitutes | 50 bolts and washers | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | McClary |
Title of sampler | ASR | Telephone number of sampler | 510-406-4613 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Golden State Bridge | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 23-0015R | |
Structure name | Carquinez Bridge EB |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Bolt - 10762840 Nut - 8000017505 Washer - 12133230 | Nut Mfg. Lot Number(s) | 474417A |
Washer Mfg. Lot Number(s) | 172932 | Bolt Specification | A325 |
Bolt Length(s) | 3-1/2" | Nut Specification | A194 |
Washer Specification | F436 | Finish | Galvanized |
Diameter/Size | 3/4" | Bolt Mfg. Lot Number | E028G1 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2024-04-10-20
DIME Test ID: 2024-04-10-20-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-04-19
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 04/17/2024
UTM: 400kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 58676 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 4/19/2024 ✔