Summary for Test 2024-04-09-5-2

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 993715
DEA: 010G1404
EFIS: 0116000129
DIST-CO-RTE-PM01-HUM-96,169-VAR
Award Date11/16/2022
Closeout DateNot set
Work DescriptionHUM 96-169 5 Bridges Rail Upgrade (Do not include in project name: STRUCTURAL STEEL, CONCRETE BARRIER, POLYESTER CONCRETE OVERLAY)
Location DescriptionHUMBOLDT COUNTY ON ROUTES 96 AND 169 AT VARIOUS LOCATIONS (Bridge Nos. 04-0215, 04-0059, 04-0063, 04-0225, 04-0061)
QA Service Level1 (Verified on 04/19/2022)

Sample Information

Sample Taken Date04/09/2024 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/12/2024
Sample typeQuality Assurance A brief description of the sampleA325 HDG Bolt
The quantity of what the sample constitutes918 Bolts From where was the sample collectedFabricator
First name of sampler or witnessed byJamie Last name of sampler or witnessed byDoe
Title of samplerAssociate Steel Inspector Telephone number of sampler(916) 838-4405
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC&K Johnson Industries Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS50-015-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)E016N1R
Heat Number(s)10848550 Nut Mfg. Lot Number(s)
Washer Mfg. Lot Number(s) Bolt SpecificationASTM A325
Bolt Length(s)3" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishASTM F2329
Diameter/Size1"-8 Bolt Mfg. Lot NumberE016N1
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2024-04-09-5
DIME Test ID: 2024-04-09-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2024-04-17

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 04/16/2024
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11BE016N11.000089240396.9610.00Wedge Tensileaauvinen

General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 4/17/2024