Summary for Test 2024-03-27-63-1

Test performed: AASHTO T59-22

Project Information

Project IdentifiersProject ID: 994443
DEA: 053307C4
EFIS: 0514000028
DIST-CO-RTE-PM05-SLO-41,46-44.5/45.3,54.0/57.8
Award Date02/27/2023
Closeout DateNot set
Work DescriptionWye Segment - Route 41/46 Separation
Location DescriptionNot set
QA Service Level1 (Verified on 12/16/2022)

Sample Information

Sample Taken Date03/27/2024 Sample Unique Key63
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/08/2024
Sample typeVerification A brief description of the sample1/2" HMA-A w/15% RAP w/las
The quantity of what the sample constitutes1 jar From where was the sample collectedJob Site
First name of sampler or witnessed byWit Last name of sampler or witnessed byK. Engen
Title of samplerTET Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePapich Construction Transportation Laboratory (TL) NumberC979518
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameGrind and Pave Ruble Strips

Material Information

Material TypeAsphaltic Emulsion Emulsion GradeSS-1h
Lot Number1 Sub Lot1

Test Details

DIME Sample ID: 2024-03-27-63
DIME Test ID: 2024-03-27-63-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T59-22: Standard Method of Test for Emulsified Asphalts (Emulsified Asphalt Residue Evap. (Sec. 7))
Test Release Date: 2024-04-10

Test Results


How many beakers will be used to conduct the test?: 2
Input Type: Measured
Tester's full name: Hamidullah Barati
Date of test: 04/09/2024
Beaker 1 Mass of beaker, rod, screen (if used), and residue: 152.7 g
Beaker 1 Tare mass of the beaker, rod, and screen (if used): 122.6 g
Beaker 2 Mass of beaker, rod, screen (if used), and residue: 152.8 g
Beaker 2 Tare mass of the beaker, rod, and screen (if used): 122.7 g
Beaker 1 Residue: 60.2 %
Beaker 2 Residue: 60.2 %
Percentage of residue: 60 %
General comments (publicly viewable) (Max 1000 characters): EVAP

Test was verified on 4/10/2024