Summary for Test 2024-04-02-37-2
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994321 DEA: 040K1604 EFIS: 0416000044 |
---|---|
DIST-CO-RTE-PM | 04-ALA,CC-80-R7.6/8.0,0.0/13.5 |
Award Date | 02/08/2023 |
Closeout Date | Not set |
Work Description | CONSTRUCT RHMA, LIGHTING SYSTEM, AND CONCRETE BARRIER. |
Location Description | ALAMEDA AND CONTRA COSTA COUNTIES IN ALBANY AND CROCKETT FROM 0.4 MILE SOUTH OF ALAMEDA COUNTY LINE TO 0.2 MILE SOUTH OF POMONA STREET |
QA Service Level | 1 (Verified on 10/14/2022) |
Sample Information
Sample Taken Date | 04/02/2024 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2024 |
Sample type | Quality Assurance | A brief description of the sample | Class 2 Aggregate Base |
The quantity of what the sample constitutes | 25000 grams | From where was the sample collected | Job Site |
First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
Title of sampler | TET | Telephone number of sampler | 5102077252 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Vallejo | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Class 2Aggregate Base |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Job site | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2024-04-02-37
DIME Test ID: 2024-04-02-37-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2024-04-08
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/02/2024
Gage No.: 691
Test No.: Rich_24_016
Nuclear By: Ignacio Arechiga
Non-Bias Plan No.: 7
Depth: 8"
Material No.: Class 2 AB
Material Type: Base
Impact By: Jose Leon
Standard Count Density: 32197 g/cc
Count or Density 1: 34666 g/cc
Count or Density 2: 34212 g/cc
Count or Density 3: 35675 g/cc
Standard Count Moisture: 8692 g/cc
Moisture Count 1: 2687 g/cc
Moisture Count 2: 2535 g/cc
Moisture Count 3: 2536 g/cc
Sum of Count or Density: 104553 g/cc
Average of Count or Density: 34851 g/cc
Sum of Moisture Count: 7758 g/cc
Average of Moisture Count: 2586 g/cc
Count Ratio Density: 1.08
Count Ratio Moisture: 0.3
Calculated Percent Relative Compaction: 2.02 %
Reported Percent Relative Compaction: 92 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/8/2024 ✔