Summary for Test 2024-04-04-7-1
Test performed: CTM 342-August 2012Project Information
Project Identifiers | Project ID: 994607 DEA: 101N5504 EFIS: 1022000004 |
---|---|
DIST-CO-RTE-PM | 10-SJ-5-R13.0,R13.9 |
Award Date | 05/11/2023 |
Closeout Date | Not set |
Work Description | REPLACE JOINT SEALS AND PLACE POLYESTER CONCRETE OVERLAY. |
Location Description | SAN JOAQUIN COUNTY NEAR LATHROP AT PARADISE CUT BRIDGE AND AT PARADISE CUT OVERFLOW BRIDGE |
QA Service Level | 1 (Verified on 04/18/2023) |
Sample Information
Sample Taken Date | 04/04/2024 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/03/2024 |
Sample type | Quality Assurance | A brief description of the sample | Skid Testing |
The quantity of what the sample constitutes | Skid Testing | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jessie | Last name of sampler or witnessed by | Wilson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Paradise Cut |
Material Information
Material Type | Roadway/Bridge Surface | Pavement Surface Type | Polyester Concrete |
---|---|---|---|
Type of Traffic Control Provided | Stationary Lane Closure | DIST-CO-RTE | 10-SJ-5 |
Direction of Travel | South | Post Mile | 012.99 |
Lanes to be Tested | Lane #5 | Station |
Test Details
DIME Sample ID: 2024-04-04-7
DIME Test ID: 2024-04-04-7-1
Testing Lab: CT HQ - FFS - Skid Testing
Test Method: CTM 342-August 2012: Method of Test for Surface Skid Resistance with the California Portable Skid Tester (Skid)
Test Release Date: 2024-04-04
Test Results
Pavement or Bridge Deck?: Bridge Deck
Input Type: Measured
Tester's full name: Jessie Wilson
Date of test: 04/04/2024
Air Temperature: 50 F
Tire Pressure: 25 psi
Equipment PST #: 1009
Is Calibration within ± values: Yes
Weather: Windy
Direction/Lane #: SB: Southbound Direction of Travel
Edge used to measure reference distance: Beginning of Bridge
Edge used to measure position: Left of Right Bridge Wall
Reference Distance 1: 17 ft
Reference Distance 2: 20 ft
Reference Distance 3: 23 ft
Direction and Lane # for Stationing 1: no data
Direction and Lane # for Stationing 2: no data
Direction and Lane # for Stationing 3: no data
Position for Stationing 1: 12 ft
Position for Stationing 2: 12 ft
Position for Stationing 3: 12 ft
Percent Grade for 1st Stationing: 0.0 %
Percent Grade for 2nd Stationing: 0.0 %
Percent Grade for 3rd Stationing: 0.0 %
Corrected Coefficients of Friction for Stationing 1: 0.43
Corrected Coefficients of Friction for Stationing 2: 0.41
Corrected Coefficients of Friction for Stationing 3: 0.41
Average Coefficient of Friction: 0.42
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/4/2024 ✔