Summary for Test 2023-11-29-53-2
Test performed: AASHTO T176-08Project Information
Project Identifiers | Project ID: 994609 DEA: 112N1194 EFIS: 1121000148 |
---|---|
DIST-CO-RTE-PM | 11-SD-94-14.9/29.2 |
Award Date | 05/18/2023 |
Closeout Date | Not set |
Work Description | MICROSURFACING, RUMBLE STRIP, PAVEMENT MARKING, & SHOULDER BACKING. |
Location Description | SAN DIEGO COUNTY NEAR JAMUL FROM JUNCTION ROUTE 54/94 TO 0.7 MILE EAST OF DULZURA CREEK |
QA Service Level | 1 (Verified on 08/23/2023) |
Sample Information
Sample Taken Date | 11/29/2023 | Sample Unique Key | 53 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/27/2024 |
Sample type | Quality Assurance | A brief description of the sample | Type III Micro-surfacing |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Source |
First name of sampler or witnessed by | Michael | Last name of sampler or witnessed by | Stewart |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0223-S | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | VSSI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Plant |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Micro-surfacing | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-11-29-53
DIME Test ID: 2023-11-29-53-2
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-04-04
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 04/10/2024
Clay Level (Test 1): 5
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5
Sand Level (Test 2): 4
Clay Level (Test 3): 5.1
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 78
Sand Equivalent (Test 2): 80
Sand Equivalent (Test 3): 79
Sand Equivalent: 79
General comments (publicly viewable) (Max 1000 characters): Test results are within specification limits.
Test was verified on 4/4/2024 ✔