Summary for Test 2024-03-13-36-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994591 DEA: 081J6704 EFIS: 0818000090 |
---|---|
DIST-CO-RTE-PM | 08-RIV-15-9.4/16.3 |
Award Date | 05/04/2023 |
Closeout Date | 11/04/2024 |
Work Description | MINOR CONCRETE, MODIFYING SIGNAL AND LIGHTING SYSTEMS, HMA AND JPCP. |
Location Description | RIVERSIDE COUNTY IN MURRIETA AND WILDOMAR AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF MURRIETA HOT SPRINGS ROAD OVERCROSSING TO BUNDY CANYON ROAD UNDERCROSSING. |
QA Service Level | 1 (Verified on 06/20/2023) |
Sample Information
Sample Taken Date | 03/13/2024 | Sample Unique Key | 36 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/18/2024 |
Sample type | Department Acceptance | A brief description of the sample | 3/4" HMA-A-SP R15 PG64-28M |
The quantity of what the sample constitutes | 2 BOXES OF HMA, 1 BAG OF RAP | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | VICTOR QC | Last name of sampler or witnessed by | VICTOR QC |
Title of sampler | QC | Telephone number of sampler | |
Laboratory sample identification | 0139A-24 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | AAA-Corona | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 105927 |
Test Details
DIME Sample ID: 2024-03-13-36
DIME Test ID: 2024-03-13-36-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-03-29
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 03/20/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2,150.2 g
Mass Loss: 107.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.80 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/29/2024 ✔