Summary for Test 2024-02-24-10-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994247
DEA: 051H8604
EFIS: 0517000002
DIST-CO-RTE-PM05-SB-101-46.2/R52.3
Award Date02/01/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC PVMT, PLACE HMA, RHMA-G, HMA-0, REPLACE MEDIAN BARRIER.
Location DescriptionSANTA BARBARA COUNTY NEAR GAVIOTA FROM 0.1 MILE NORTH OF GAVIOTA BEACH STATE PARK TO OLD COAST HIGHWAY
QA Service Level1 (Verified on 09/23/2022)

Sample Information

Sample Taken Date02/24/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2024
Sample typeDepartment Acceptance A brief description of the sampleCalcined Bauxite
The quantity of what the sample constitutes2 Bags From where was the sample collectedSource
First name of sampler or witnessed byJohn Last name of sampler or witnessed byKopevil
Title of samplerSales Manager Telephone number of sampler
Laboratory sample identification24-0043, 24-0059 Linked DIME Sample ID
The fabricator/manufacturer/facility nameFX Minerals Processing, Inc. Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHigh Friction Surface Treatment Mgf. Lot Number(s)24-0614D
Batch NumberUnknown Mix NumberUnknown
Resin Binder TypeEpoxy Used for OverlayYes
Used for InlayNo

Test Details

DIME Sample ID: 2024-02-24-10
DIME Test ID: 2024-02-24-10-3
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-03-28

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Individual Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Aristeo Flores
Date of test: 03/08/2024
Cumulative percent passing the 3/8 in. sieve: 100 %
Cumulative percent passing the #4 sieve: 100 %
Cumulative percent passing the #8 sieve: 98 %
Cumulative percent passing the #16 sieve: 3 %
Cumulative percent passing the #30 sieve: 0 %
Cumulative percent passing the #50 sieve: 0 %
Cumulative percent passing the #100 sieve: 0 %
Cumulative percent passing the #200 sieve: 0 %
General comments (publicly viewable) (Max 1000 characters): Special gradation for HFST. A #6 sieve was used in lieu of the #8 sieve above. #30-#200 are representative of the pan for this purpose.

Test was verified on 3/28/2024