Summary for Test 2024-03-16-20-2

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 214469
DEA: 030H08U4
EFIS: 0319000029
DIST-CO-RTE-PM03-SAC-50-L0.2/R6.1
Award Date06/30/2020
Closeout DateNot set
Work DescriptionSac 50 Design Build PLEASE NOTE THAT DESIGN BUILDER MUST PERFORM QUALITY VALIDATION TESTING IN ACCORDANCE WITH THE MATERIAL CONTROL SCHEDULE (MCS) FOR ITEMS SUCH AS STRANDS, HS BOLTS, ELASTOMERIC BEARING PADS, JOINT SEALANTS, COUPLERS & WELDED HOOPS, ETC
Location DescriptionFROM 0.1 MILE EAST OF I-5 TO 0.8 MILE EAST OF WATT AVE
QA Service Level1 (Verified on 10/23/2019)

Sample Information

Sample Taken Date03/16/2024 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/26/2024
Sample typeQuality Assurance A brief description of the sample2 Boxes of Mix
The quantity of what the sample constitutes3/4" HMA From where was the sample collectedJob Site
First name of sampler or witnessed bySergio Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identificationDaily 24-006 Linked DIME Sample ID2024-03-16-17
The fabricator/manufacturer/facility nameTeichert Perkins Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number5
Sublot number3 HMA Mix Number

Test Details

DIME Sample ID: 2024-03-16-20
DIME Test ID: 2024-03-16-20-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-03-27

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 03/27/2024
Specific Gravity for Sample 1: 2.556
Theoretical maximum density at 25°C (77°F): 3 kg/m^3
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 3/27/2024